This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
|
instrumentation:start [2019/05/20 05:35] admin created |
instrumentation:start [2022/07/04 17:57] (current) admin [Dataloggers] |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ~~NOTOC~~ | ||
| ====== Instrumentation ====== | ====== Instrumentation ====== | ||
| + | |||
| + | * :!: [[.:Los Amigos: | ||
| + | |||
| + | ===== 1. Eddy Covariance (10Hz) ===== | ||
| + | * Licor Li-7200 Closed Path CO2/H2O Gas Analyzer \\ with heated intake | ||
| + | * Campbell Scientific CSAT3 – 3D Sonic Anemometer | ||
| + | * Campbell Scientific CR3000 data logger | ||
| + | |||
| + | |||
| + | ===== 2. Meteorology (1Hz) ===== | ||
| + | * Hukseflux NR01 4-component Net Radiometer | ||
| + | * Vaisala HMP155 T/RH sensor | ||
| + | * DeltaT BF3 Radiometer | ||
| + | * Licor Li-190R PAR sensor | ||
| + | * Hyquest Solutions TB4 Rain gauge | ||
| + | * Campbell Scientific CR3000 data logger | ||
| + | |||
| + | ===== 3. CO2 Profiling system (hourly) ===== | ||
| + | * Licor Li-820 CO2 Gas Analyzer \\ with intakes at 0.5, 1, 2, 4, 8, 16, 32, 45m (equal length tubing) | ||
| + | * Campbell Scientific CR1000 data logger | ||
| + | |||
| + | ===== 4. Calibrated CO2 system ===== | ||
| + | * Licor Li-840 CO2 Gas Analyzer plus pumping and gas drying system. | ||
| + | * Campbell Scientific CR1000 data logger | ||
| + | * Four cylinders with calibrated CO2: 380, 389, 405, 419ppm | ||
| + | |||
| + | ===== 5. Additional Sensors ===== | ||
| + | * 2 Apogee infrared radiometers (canopy temperature) | ||
| + | |||
| + | ===== 6. Data Transmission ===== | ||
| + | |||
| + | * Digi Transport WR31 Router | ||
| + | * VPN coming soon ... | ||
| + | |||
| + | ===== 7. Wireless Sensor Network with LoRa Transceivers ===== | ||
| + | |||
| + | * coming soon ... | ||
| + | |||
| + | ===== 8. Soil Sensors ===== | ||
| + | |||
| + | To be installed in June | ||
| + | |||
| + | * Campbell Data Logger CR6 | ||
| + | * Hukseflux Heat Flux plates | ||
| + | * TDR profiler: [[https:// | ||
| + | |||
| + | |||
| + | ====== Installation 2022 ====== | ||
| + | |||
| + | * Solar Induced Fluorescence (https:// | ||
| + | * Ecomatic Ecomatic Dendrometer | ||
| + | |||
| + | |||
| + | ====== Dataloggers ====== | ||
| + | |||
| + | * LTE Datalogger, | ||
| + | * Licor Campbell CR3000 | ||
| + | * NOAA Campbell | ||
| + | * Heat flux plates | ||
| + | * SIF | ||
| + | * LoRa | ||
| + | |||
| + | |||
| + | |||
| + | |||